Isolation, Method Development, and Validation of Diterpenes in Coffee Oil: Identification by Multiple Reaction Monitoring Approach with Atmospheric Pressure Chemical Ionization Mode

Articles

Abstract
Pharmacognosy Research,2021,13,1,42-48.
Published:April 2021
Type:Original Article
Authors:
Author(s) affiliations:

Naveen Puttaswamy1, Lingaraju Harakanahalli Basavegowda2, Deepak Machettira2, Chandrappa Siddappa2, Rashmi Ramesh1, Shyam Prasad Kodimule2

1Analytical Research and Development, Vidya Herbs Pvt. Ltd, Bengaluru, Karnataka, INDIA

2Phytochemistry Lab, Vidya Herbs Pvt. Ltd., Bengaluru, Karnataka, INDIA

Abstract:

Objectives: The aim of the present study is to isolation, identification, and quantification of free diterpenes in coffee oil of Coffea arabicaMaterials and Methods: For the isolation of free diterpenes, saponification reaction step was employed and followed with a liquid-liquid extraction procedure applied. Cafestol and kahweol were identified by multiple reaction monitoring (MRM) of positive ionization (MRM) mode of atmospheric pressure chemical ionization (APCI) mass spectrometry detection. The quantification of free diterpenes was done by high-performance liquid chromatography with diode array detector. The developed method was validated according to the international conference on harmonization guidelines. Results: The ion transitions of the precursor to the product ion at (M + H)+ m/z 317.20→146.90, 281.00, 299.00 for cafestol and 315.10→144.90, 278.90, 296.90 for kahweol were observed. The proposed method was validated for linearity with excellent correlation coefficient of cafestol and kahweol were found to be 0.9997 and 0.9996, respectively. The intra-day and intermediate precisions and repeatability showed the percentage relative standard deviation was <1%. The recovery rate for cafestol and kahweol were observed to be in the acceptable limit of 95.303%–98.539% and 95.963%–97.174%, respectively. The limit of detection of cafestol and kahweol were found to be 6.81 and 7.35 ppm, respectively. The limit of quantitation (LOQ) was found to be 22.72 and 24.52 ppm, respectively. Conclusion: The developed method is simple, rapid, precise, accurate and it is recommended for efficient assays in routine work.

PDF
Current View
Click here to download the PDF file.
Images

Isolation, Method Development, and Validation of Diterpenes in Coffee Oil: Identification by Multiple Reaction Monitoring Approach with Atmospheric Pressure Chemical Ionization Mode

Keywords